Installation of a water heater will provide owners of country houses with hot water, increase the comfort of apartments from the old housing stock such as the Khrushchev and small-family dormitories. The indefatigable unit will be hardworking to prepare and supply water to the taps, so that the owners enjoy the benefits of civilization.
So it will be, if the connection diagrams of the water heater to the water supply system are strictly followed, agree? Full answers to a wide range of questions that arise before installing water heaters and in the process of including them in a communication network, you will find on our website.
Reliable information will be useful to independent masters who want to carry out installation with their own hands. It is also necessary for customers of plumbing services to check the quality of work.
The article describes in detail the types of water heaters, their design differences are indicated, the specifics of the connection are indicated. Valuable tips are provided to ensure that the equipment works perfectly after installation. The information content of the proposed material is perfectly complemented by photo images and video recommendations.
Types of domestic water heaters
Features of connecting household heaters are directly related to the types of devices, their technical parameters, and overall dimensions.
Traditionally, two types of heaters are used in domestic practice:
- Cumulative.
- Flowing.
Both types of boiler systems differ from each other in heating technology.
The device of the accumulative type equipped with an electric heater (TEN). Such equipment is most often used in the domestic sphere. It can be mounted directly in the bathroom, if the overall dimensions allow
Storage heaters cold water is collected in a tank, heated and then discharged to the drawdown.
Flow units heating is carried out directly during the flow of cold water in contact with the heater, without collecting liquid in the storage tank.
Consumers of the domestic sphere mainly use storage boiler systems. A comparative review of both types of water heaters is given in this article.
Technical device for storage boiler
A storage-type water heating system, boilers, in a simplified diagrammatic form, is a tank equipped with electric heating elements or liquid heat exchangers. The storage vessel has pipe lines for the supply of hot water and the output of hot water.
More powerful and volumetric design - indirect heating installation. It is clear that in this case the source of heating energy is water coming from the heating system. However, if desired, it is possible to connect electric heating
The designs of indirect heating boilers are additionally equipped with a working zone of the coolant and lines for connecting to heating.
Any modern system, regardless of design features, is equipped with automation, due to which the temperature of water heating is adjusted and the system as a whole works.
Structural design of heaters
There are designs of storage boilers designed for installation vertically (wall) and horizontally (floor). Of course, in each individual case of the use of certain boilers, there are their own mounting features.
So, if wall mounting of a water heating device is supposed, a preliminary calculation of the load and comparison of the results with the design parameters of the wall of the room on which the device is to be mounted is necessary.
Recently, instantaneous water heaters are rapidly gaining popularity. Users are attracted by their small size, the possibility of a simplified easy installation. Really convenient devices for small water consumption needs
Installation of equipment without load calculations threatens to result in a fatal installation error, when a filled boiler can simply collapse along with the flimsy partition on which it was mounted.
According to the instructions for the equipment, the load must be calculated taking into account the fourfold weight of the boiler system.
Therefore, if the structure of the supporting wall is frankly weak, the water heater circuit must be supplemented not only with lines for connecting to the water supply and coolant, but also with reinforced racks - through fasteners.
Horizontal boiler plant used for local hot water supply. It also provides for electric heating and in this installation option an expansion tank is installed, which is the right solution
On the classic wiring diagrams for wall mounted boilers, the inlet / outlet pipes of the heating apparatus are marked with the corresponding color - blue / red.
Wiring diagrams and solutions
You can connect a heating device to a centralized supply in one of two ways: through a security group or directly.
A security group consists of a set of the following elements:
- shut-off crane;
- Check Valve;
- safety valve;
- expansion vessel.
Option number 1. The presence of a safety group is traditionally used in indirect heating boilers, as well as when the pressure of the centralized system is higher than the boundary parameter of the working pressure of the boiler.
The classic scheme of indirect heating equipment. Two safety groups are used: 1 - boiler safety group; 2 - an expansion vessel; 3 - safety group of the boiler; 6 - heating circulation pump; 7 - boiler circulation pump (+)
Option number 2. Direct connection is usually applicable to equipment of small capacity, with a flowing principle of operation. Direct connection is also allowed under lower and more stable centralized water supply pressures. The wiring diagram in any case involves the installation of shut-off valves.
In order to be able to carry out conservation and repair of water heating equipment, it is equipped with shut-off valves at the inlet and outlet of the system (+)
Criteria for error-free installation of equipment
Among the main moments of installation, on which attention should be paid so as not to make mistakes - this is the correspondence of the diameters of the pipelines with respect to the inlet fittings, as well as the cross-section of the cable supplying the boiler electric heater.
The diameter of the supply pipes should provide a free flow of water along the inlet / outlet lines. Therefore, a larger diameter of the sleeves with a transition to the size of the fittings is still acceptable, but the cross-section of the pipelines is smaller than the inlet pipes of the boiler, it is already a blunder.
A good example of equipping an electric heating boiler installation with all the necessary fittings. It is also worth noting here the qualitatively (accurately) made insulation of all suitable and outgoing lines
The cross section of the supply cable is similar. A cable of a larger section is not prohibited, and a cable of a smaller section is strictly prohibited.
True, the cable increased against the norm of the cross-section creates difficulties when laying in the channels, takes up more free space. Here, it seems logical to accurately select the cross section of the wire depending on the load current.
The power outlet is usually mounted directly on the unit. The height of installation of the outlet from the floor level is not less than 1.5 m. Household boilers are designed for power supply by single-phase alternating current 220-250 W. The current load is usually not less than 10 A.
Connection of the boiler system according to the electric circuit. Such a variant of the compounds can be considered made faultlessly. The wire cross section is as specified in the documentation, the ground circuit is present
The exact value is determined by the performance of the heater and is indicated in the technical documentation. It is to the specified current value that it is necessary to select a circuit breaker.
For example, for flow heaters, the following current cutoff standards for automatic machines are relevant (table):
Boiler power (flow diagram), kW | Cutoff current, A |
3,5 | 20 |
5,5 | 25 |
6,5 | 30 |
As a rule, all required connection parameters are specified by the boiler manual. The user manual accurately explains all the points of installation. Therefore, it is recommended that you carefully study the documents that are included with the machine before installation.
Some features of the water supply circuit
Connecting the storage boiler. Cold water is supplied to the boiler system through a piping line that connects directly to the centralized riser.
At the same time, a number of components necessary for the normal functioning of the equipment are mounted on the cold water line:
- Stopcock.
- Filter (not always).
- Safety valve.
- Drain cock.
The indicated circuit elements are installed in the area between the cold water supply pipe and the boiler in the marked sequence.
The hot liquid outlet line is also equipped with a shut-off valve by default. However, this requirement is not mandatory, and if the faucet at the outlet of the hot water supply is not supplied, no serious error can be seen in this.
All water heater connection schemes have common features. The cold water supply point is located below, filters and a reducer must be installed in front of it to reduce the flow pressure (+)
Connection of instantaneous water heater. Compared to the storage boiler, the work is carried out according to a simplified scheme. It is enough to install only one stopcock in front of the inlet fitting of cold water.
But the installation of a shut-off valve at the outlet of the hot water supply of a flow heater is regarded by many manufacturers as a gross installation error.
It should also be noted: if a well, a well, a water tower, etc. acts as a source of cold water for a flowing water heater, it is recommended to include a coarse filter in series with the tap (after the tap).
Often, a mounting error with connecting a filter or failure to install it will void the manufacturer’s warranty.
Frequent installation errors for water heaters
The rules for the installation of such equipment provide for the use of insulation on the HVS / GVS pipelines. Moreover, the technical requirements for installation determine the minimum possible size of the insulation thickness - 20 mm.
The thermal conductivity of the insulating material should be at least - 0.035 W / m2.
An example of insulation of a heater system, where obvious errors are noted. It is necessary to isolate not only pipes, but also working components installed in the pipeline section. Modern insulating materials make this easy.
When installing water heaters, they often violate the connection scheme of the home unit to the water supply, using insulating material of small thickness, or do not use insulation at all.
As a result, when the full operation of the device begins, significant losses of thermal energy are noted. These losses are reflected in the heating time, which increases significantly.
Improperly made or missing insulation is the main cause of condensation on the cold water line. This state of the system reduces the level of user comfort, contributes to the formation of an unsanitary environment inside the premises where the equipment is located.
A common mistake should be the installation of a boiler without an expansion vessel. The scheme, where the introduction of an expansion vessel is envisaged, is relevant specifically for storage-type water heaters.
Thanks to the expansion vessel, it is possible to compensate for the increase in pressure caused by the increase in the volume of water in the boiler storage.
Installed expansion tank in the indirect heating system. In fact, the installation of the expansion vessel failed. This element of the system should be located above the line of the upper cover of the boiler. In addition, there is no pipe insulation.
As a rule, the installation of storage heaters is limited to the inclusion of a safety valve in the section of the cold water main. Such a peculiar replacement of the expansion tank with a safety valve is permissible, but, from the point of view of proper installation, this is a technical error.
In fact, an expansion vessel with a non-return valve must always be installed on storage boilers.
List of other installation errors:
- the electric cable is laid on sharp metal edges or on surfaces with high temperature;
- the order of connecting the trunk lines does not correspond to the order indicated in the diagram;
- the installation level of the water heater relative to the horizontal and vertical is violated;
- there is no ground loop of the water heater;
- the parameters of the electric network where the equipment is connected do not meet the passport requirements;
- installation is carried out in a room where there is no water supply and sanitation system.
Any, even insignificant error in the installation of water heating equipment can play a fatal role after the start of operation of the device.
We offer you to familiarize yourself with detailed installation instructions for a storage and instantaneous water heater:
- Do-it-yourself water heater installation: a step-by-step guide + technical standards
- DIY instantaneous water heater installation: step-by-step instruction
The operation of the hot water supply system and the heating system depends on the correct installation of water heating devices, so it is important to take into account all the installation nuances. A few practical tips are presented in the videos.
Professional advice:
Recommendations for self-installation:
It is always recommended to carefully monitor the progress of installation work, being guided by the parallel documentation attached to the installation of a specific boiler model.
Often, users mount the system without bothering to look at the attached circuit. Connect two water tubes and insert the plug into the outlet - such actions for them seem to be commonplace. But the technique of mistakes does not forgive.
Do you have personal experience installing and connecting a water heater? Want to share your knowledge or ask questions about the topic? Please leave comments and participate in discussions - the feedback form is located below.