Damage to plumbing equipment is one of the most common causes of leaks. Agree, being the culprit of the flood and its victim is both unpleasant and financially unprofitable.
The “anti-flood” system installed in time will help to avoid a catastrophe even in case of damage to pipes and violation of the integrity of the water circuit. Before you install a water leakage sensor yourself, you need to understand the mechanism of the mechanism and the features of the work of different models.
We will talk about the design features and the principle of operation of the device. Let us explain the procedure for assembling the protective system and connecting the controller. Visual photo instructions, thematic videos help you choose a device and install it yourself.
The principle of the system against leakage
The principle of operation of any stationary anti-leakage system is based on the difference between the electrical conductivity of water and air. The basis of any sensor is an ordinary pair of electrodes.
If water gets on them, then the resistance decreases and an electrical circuit closes. Information about the circuit closure goes to the controller, where the decoding of the pulse and the processing of information.
After that, the controller sends its signal to close the solenoid valve located on the riser, directly on the input.
Image Gallery
Photo from
The water leakage sensor is a small device designed to record and transmit emergency information
Sensors included in the leakage protection system of the house / apartment are installed on all circuits along which water moves, in particular, on water heating devices
Water leakage fixation devices are placed near equipment that actively consumes water: washing and dishwashers, boilers, etc.
Sensors that record the fact of water leakage are equipped with water pipes, plumbing fixtures and water taps
Leakage sensor is one of the components of the flood protection system. His duty to detect an accident and transmit information to the controller, which notifies the owners of the premises
In addition to the sensor and controller, the emergency leakage protection system includes a ball actuator designed to shut off water at the command of the controller
A leakage protection system should be installed in order to prevent irreparable damage to your own property and decoration
Installing a system with water leakage sensors will help to avoid a lot of unpleasant situations associated with paying for damaged property of neighbors
Appearance and dimensions of the water leakage sensor
Leakage protection system for water heating
Leak detection device near equipment
Breakthrough of a water pipe from excess pressure
Standard leakage protection components
Ball actuator for shutting off water
Protection of own property and decoration from damage
Prevention of flooding of neighbors' apartments
The inlet valve will be closed until the cause of the leak is identified and completely eliminated. After performing simple manipulations with the controller, the system will resume operation.
The stationary system works autonomously and requires intervention only in case of leak detection and troubleshooting.
After moisture gets on the electrode, the circuit closes, the signal of which is transmitted to the controller. The electromagnetic valve closure time varies between 2-30 seconds and is determined by the type of protection system selected (+)
Classification of leakage protection systems
Anti-leakage systems are classified according to the following main features:
- By the number of electric cranes included.
- By the method of reporting leaks.
- By the method of exchanging information between sensors and the control unit.
As a rule, the number of electric cranes in the kit should be at least two. This is due to the fact that taps must be installed on risers of cold and hot water. The number of cranes, depending on the selected system, can be increased.
Types of models by notification method
The following methods for leak reporting are:
- indication on the controller display;
- Indication on the display, accompanied by noise signals;
- noise alarm, indication and message sending.
Messaging is possible if the system is equipped with a GSM transmitter. In this case, an SMS message is sent to the phone number that is stored in the device’s memory.
Entering a phone number is made from the control panel. When connecting the system to the Internet, it is possible to send messages via GPRS connection.
The magnetocontact sensor is equipped with a GSM alert function for 6 phone numbers. Thanks to this, all residents of the house or apartment will be notified about the leak almost simultaneously.
The information displayed on the control panel varies by model. Most often, information is displayed on the presence of leaks, the condition of the sensors, the level of charge of the batteries and batteries.
Wired and Wireless Sensors
Signals from water leakage sensors can be transmitted to the controller, both via wires and radio channels. In this regard, it is customary to distinguish between wired and wireless systems focused on flood prevention.
In wired systems A voltage of up to 5 V is applied to the sensor when transmitting information. In case of a dry surface, there is no current due to the high resistance between the contacts. As a result of exposure to moisture, a decrease in resistance and an increase in current occur.
A small voltage is applied to the sensor electrodes through the wires, however, due to the high resistance between the contacts, there is no current. When exposed to moisture, the resistance drops and the circuit closes
To eliminate false alarms, you must set the minimum current threshold at which the controller closes the solenoid valves.
This is due to the fact that the resistance between the contacts decreases when steam is formed or water is sprayed, but its value remains quite high and does not reach the minimum values, as a result of leakage.
Inside each wireless sensor There is a current comparison circuit that is triggered when the set value is reached. A special transmitter constantly measures the contact resistance and, upon flooding, immediately sends a radio alarm signal to the receiver. The receiver and transmitter are tuned to the same frequency.
A special transmitter detects an increase in resistance at the sensor contacts and gives a radio alarm signal, which is received by the radio receiver of the control unit
The transmitter signal is modulated in order to avoid false alarms due to electromagnetic interference.
Each of the manufacturers applies its own modulation principles. In this regard, wireless sensors for monitoring water leakage cannot be used in other leakage control systems.
Typical protective system
The most popular among consumers are the following leakage alarm systems operating on the same principle:
- Neptune;
- Aquastorozh;
- Gidrolock.
In the presented systems, ball valves with an electromagnetic or electromechanical valve with a diameter of ½, ¾, 1 inch are used. Devices not only provide shutoff of the crane, but also inform about leakage.
Any typical leakage alarm system consists of the following standard components: a controller - a control unit (1), an electric ball valve (2), sensors (3) (+)
Water leakage systems can be integrated with Smart Home systems.
The leakage protection package includes:
- Ball Valvesequipped with electric drive. They are designed to completely or partially block the water supply or heating circuits in case of leakage. The device is mounted directly after the inlet valves.
- Controllerrepresenting a control unit. Designed to perform just one operation - shutting off a motorized crane after receiving and processing a signal from one of the sensors. In addition, the controller is responsible for the notification of leakage and power sensors. The controller can be installed in any convenient, but at the same time accessible place.
- Leakage sensors. When moisture enters, a leakage signal is given. They are connected exclusively to safe energy sources. Sensors are installed in places most often threatened with leaks: under showers and sinks, behind toilets, near washing machines, in places where flexible hoses are connected, etc.
Sensors can be autonomous, as in the system Hydrolockand volatile, both in cheaper protection "Neptune".
The leakage alarm system uses electric ball valves. The only negative is that such devices are needed for both hot and cold water, because the system does not respond to the temperature of the flowing fluid
In autonomous water supply systems, the function of a tap with an electric drive can be performed by a pump, which turns off after a signal from the sensor about a leak is received. But even in this case, it is undesirable to neglect the installation of a ball valve equipped with an electric drive.
Even if the pump turns off and the water supply from the well or the well stops, in the absence of a shut-off inlet ball valve, the system will not be fully protected against leakage.
This is due to the fact that water from the accumulator can enter the malfunctioning system. Therefore, the installation of "controlled crane" is considered a necessity.
Rules for installing the system against the flood
The main advantage of any modern leakage protection system is the ease of assembly and the speed of installation work. By purchasing a flood warning system, you get a kind of designer, the individual parts of which are connected using special connectors.
A significant advantage of factory-made leakage and emergency flood alarm systems is the ease of assembly and installation of components (+)
The installation of the system should begin with a detailed diagram, which will clearly indicate the location of each of the components. After the development of the plan, it is necessary to check the length of the wires and determine whether it is enough to connect sensors and cranes to the control unit.
Installation work is carried out in the following order:
- Marking of areas on which the installation of the controller, cranes and sensors is provided.
- Laying and connection of installation wires.
- Insert ball valves equipped with shut-off valves with electromechanical or electromagnetic actuators.
- Installation of leakage sensors.
- Installation of the control unit (controller).
- Connection and verification.
One of the most difficult aspects of installing leakage protection is the insertion of ball valves. A mistake when tapping cranes can nullify all efforts.
Image Gallery
Photo from
Preparing for installation of a leakage protection system
Installation of ball valves with electric drive
Security Controller Location
Mounting holders for installing leakage sensors
Installing leakage protection sensors
Mounting the sealed sensor cover
Connecting to the system component controller
Verification of installation work
Ball valve
Before carrying out work, it is necessary to block the taps located at the entrances of the risers of cold and hot water. Next, directly behind the tap, the pipeline should be cut and the hot and cold water meters neatly - the seals should remain intact.
After that, the valve of the system must be screwed onto the crane or to a pre-installed exhaust. Now it remains to reinstall the meter and reconnect previously removed pipes.
The complexity of the work depends on the type of pipes of the water supply or heating system. The easiest way to work with metal-plastic pipes is to connect the elements and press them with a lock nut.
Ball valves can also be located after metering stations, but then the section of the water supply system from the inlet valve to the electric valve remains without control
If the water supply or heating system is made of propylene pipes, then complex soldering can be replaced by using special detachable couplings used for repair purposes.
After installing the cranes, you need to connect them with a separate power line to the junction box of the controller that provides power to the locking unit.
Installing water leakage sensors
With the installation of water leakage sensors with your own hands, there should not be any difficulties. Sensors should be located in areas with a high risk of leaks:
- under showers and bathrooms;
- behind sinks and wash basins;
- near toilets, washing machines and dishwashers.
If the floor has a slope, then the sensor must be installed in the lowest place.
There are two sensor layouts:
- internal;
- outdoor.
Manufacturers recommend giving preference to the internal placement of sensors, in which devices crash into tiles or other flooring.
Internal location. The sensor contact plates must be brought out and placed 3-4 mm above the floor. This arrangement will prevent false alarms in the event of wet cleaning or accidental spraying of water. The wire to the sensors is led in a waterproof corrugated pipe.
External location. Sensors are laid directly on the floor with the contacts down. The sensor body can be fixed with building glue or double-sided tape.
The external arrangement of devices is most often used if the leakage control system is installed after finishing the installation and installation of plumbing.
When installing the sensor externally, it must be placed with the plates down and fixed with construction glue or tape. The sensor should be easy to remove for maintenance.
Do-it-yourself installation of a water leakage sensor will be even less difficult if the system has wireless sensors.
In this case, you don’t have to worry about the aesthetic side of the issue, you don’t need to ditch the walls and floor or mask the wires in the baseboard. The wireless sensor is easily mounted on any surface, as it is equipped with fasteners.
Controller Installation Rules
The controller should be located in a convenient place for maintenance. It is best to place the controller near the shut-off valves, it can be mounted on the wall using brackets or hidden in a niche.
Note that the power cabinet provides power to the control unit, so phase and zero must be connected to the controller.
The controller can be installed in almost any convenient place, but it is best to place it close to the wiring and shut-off valves, so you will have to lay the wire less
After fixing the controller, you can connect it to the mains and connect the electrically controlled valves.
The wires are connected through special terminal connectors, numbered and signed for ease of installation. The controller and instructions clearly indicate where and what wire should be connected.
It remains to connect water leakage sensors to the appropriate connectors and the assembly of the system can be considered completed. If the standard length of the wire is not enough, then it is necessary to perform their extension. Manufacturers guarantee the operation of the system even if the sensor is 100 m from the control unit.
System Check
After pressing the power button, the controller will diagnose and confirm that it is ready for operation with the green indicator light. Before you entrust the security of your home to the system, it will not be superfluous to carry out its diagnosis.
To do this, moisten the plate of one of the sensors with water. If the system is working correctly, you will hear a beep, the indicator light will turn on or flash red, and the electric valves will shut off the water supply.
After water enters the sensor contacts, the controller gives a noise and sound signal, at the same time shutting off the solenoid valves in a matter of seconds
To unlock the system, wipe the sensor dry and reinstall. The power of the controller must be turned off and on again. After the self-diagnosis, the water leakage control system is ready for use again.
How to choose a flood protection
In terms of efficiency, cheap and expensive devices are almost the same, with the exception of factory defects that can be in any system. Each of the manufacturers presents its product, but this is just an advertisement and no more.
Logo leakage protection system Hydrolock the complete supply provides for the presence of 3 sensors, while you can connect another 40 sensors without installing additional units.
Protection Complexes Aquastorozh initially equipped with 4 sensors and you can connect 10 more. If you install additional units, the number of sensors can be brought up to 375.
Included system Neptune there are only 2 sensors, the rest need to be purchased separately. In this case, without installing additional units, the system can support no more than 10 sensors for water leakage.
A wireless sensor system significantly increases the cost of the system, so if you are comfortable with a wired system, it is better to give preference to it. Also, the cost of the system increases if it is possible to install additional cranes.
As we have found out, for efficient operation you need no more than 2 ball valves with electromagnetic valves mounted on cold and hot water risers behind the inlet valves. Buying a system with 6-8 cranes, you will overpay for something that you will never use.
When advertising their products, some manufacturers speculate with such magnitude as operating voltage. And it for protection systems ranges from 5-12 V.
At the same time, the current strength in the sensor wires is absolutely safe, and the current in the crane wires, although it reaches 1 A, lasts only a few seconds, so the difference in operating voltages is completely insignificant.
One of the main indicators of the effectiveness of the system is the time of the overlap of the crane. In cheap systems Neptune this figure reaches 30 seconds, while the most modern systems Aquastorozh able to shut off cranes in just 2-3 seconds.
Please note that if a heating pipe or water pipe breaks in 20 seconds, 20-25 liters of water can pour out.
Another important indicator is the presence of a battery in the kit, which ensures the autonomy of the system in the event of a power outage.
Overview of the Neptune leakage control system package and installation tips:
Aquastorozh kit review:
Most protection systems against emergency water leaks are self-sufficient - they are able not only to control leaks, but also periodically monitor the sensors, determine the battery level, and clean the electromagnetic valves.
Modern anti-leakage systems are completely autonomous and require human intervention only to eliminate the accident.
Looking for an effective sensor to protect against leaks? Or have experience using such devices? Please leave comments on the article, ask questions and share your impression about the use of anti-flood protection systems.