From the point of view of the cost of energy resources and ease of maintenance, the optimal solution of all the options for devices for heating a house can be called gas equipment.
If it is necessary not only to heat the room, but also to provide the house with hot water, then a double-circuit floor gas boiler capable of serving both compact houses and spacious apartments will be the best choice.
The buyer is facing a difficult task. Agree, it’s quite difficult to navigate the variety of proposals of manufacturers of heating units.
We will help you understand the device and the specifics of the operation of different models, outline the main parameters of a competent purchase, and also give practical recommendations for choosing a gas boiler.
Convection or condensation boiler?
What you need to know about the characteristics of such equipment, its design and operational features, let's try to figure it out.
Convection gas floor-standing boilers use heat to heat the coolant, obtained from the energy that is released during the combustion of gas. At the same time, a large amount of heat, together with steam and flue gases, goes into the atmosphere.
The efficiency of convection gas boilers is expressed in terms of efficiency and often does not exceed 85-90%
Although convection boilers are not considered the most efficient, from the point of view of economy, their existence in the heating equipment market justifies a number of advantages. These include simple construction, reasonable cost, compact dimensions, easy installation and repair.
Condensing boilers are considered the most economical and efficient - they are 20% more efficient than convection heating devices. Higher efficiency is obtained thanks to an additional heat exchanger, which also uses steam energy (+)
One of the disadvantages of condensing boilers can be considered a relatively high cost. The latter factor, however, quickly pays off, since there is a noticeable decrease in gas consumption. The second is the difficulty of disposing of condensate, which cannot be easily drained into a septic tank so as not to destroy the bacteria processing waste water.
The principle of operation of a condensing double-circuit boiler allows you to reduce gas consumption, get much more energy with equal fuel consumption (+)
Type of power supply: non-volatile or not
The principle of operation of a volatile boiler is as follows: the installed automation detects with the help of sensors the activation of the domestic hot water system or a decrease in the temperature in the heating circuit and includes heating.
The heat carrier passing through the heat exchanger is heated to the required temperature and is supplied to the circuit of the heating system or hot water supply using a circulation pump.
It is understood that a volatile device will consume electricity. To reduce its consumption, it is better to choose models with energy class A ++. But, in addition to energy consumption, it is necessary to take into account the cost of repair, replacement of spare parts, automation.
For example, breakdown of electronic boards is a fairly common occurrence, repairs are expensive, and replacing a part with a new one will cost almost half the cost of the boiler itself.
Energy-dependent boilers are more technological, they maintain the temperature in a certain mode, save more gas
But non-volatile models can be called the most adapted to the conditions when the electricity is turned off, and energy fluctuations make you worry about the integrity of the automation.
Heating principle: flowing or storage
The flow-through heating principle can be carried out by two types of heat exchangers:
- separate;
- bithermic.
Both of them have advantages and disadvantages, so the choice may depend only on the buyer of the equipment and his preferences.
Separate heat exchanger boiler has a primary (intended for heating) and secondary (used for water heating) heat exchanger. The secondary heat exchanger has a built-in circuit, which serves to heat the water that is heated, taking heat from the heat carrier of the heating circuit.
This type of boiler cannot simultaneously operate in the heating and water heating mode: as soon as one system is put into operation, the second one is suspended.
The disadvantage of flowing double-circuit floor boilers is the overexpenditure of cold water, which will have to drain before warm water enters the tap. In addition, when using water from two or more points at the same time, the pressure in the hot water system will be uneven, as well as the temperature of the water in the taps (+)
In bithermic heat exchangers water is heated by a burner located in the tube, which passes inside the main heat exchanger. In such equipment, the water heats up much faster. Such boilers are more compact and cheaper.
A significant drawback of bithermic boilers is the temperature difference in the hot water supply. This leads to the fact that immediately after opening the tap can go very hot water.
For those houses where consumption is not so large, the operation of double-circuit boilers is quite capable of providing the minimum needs for warm water. But if consumption is planned in large quantities, it is better to provide a more powerful option - a boiler with a boiler connected, in which a certain supply of hot water will accumulate (+)
Double-circuit floor gas boilers with a built-in tank, unlike flow models, can provide full water. The volume of tanks varies from 25 to 60 liters. For heating large volumes use devices with high power. You can further increase productivity with the help of boilers combined in cascades.
Heat exchanger materials: which is better
The heat exchanger plays one of the main roles in the design of a gas heating device - the coolant circulates through it. The most common materials used in the manufacture of heat exchangers for gas boilers are copper, cast iron, steel.
Steel heat exchanger option
The cheapest and, as a result, the demanded material for the heat exchanger is steel. Therefore, it is actively used by domestic manufacturers in order to reduce the cost of the final product. Unlike cast iron, brittleness is not characteristic of it.
Compared to cast iron, steel is much lighter, but when compared with copper, it significantly exceeds its weight and makes the boiler design heavier.
The steel heat exchanger heats up quickly and cools down. In addition to convenience, this leads to negative consequences - the "fatigue" of the metal causes damage. The downside of steel is also its susceptibility to corrosion.
During operation, both the inside and the outside of the steel heat exchanger undergo corrosion. Over time, this leads to its destruction.
Copper type heat exchanger
The material has many positive properties - corrosion resistance, small volume, low inertia. Due to its compactness and low weight, copper is actively used for the production of light wall-mounted boilers.
Corrosion-free - one of the main qualities for heating equipment, which is designed to heat process water
Manufacturers of modern heating equipment have long been refuted by the opinion of the fragility of copper heat exchangers - in them the burner power is reduced by 30%, which reduces the thermal effect on the metal and has a good effect on the duration of the operation.
Cast iron heat exchanger boilers
The main quality of cast iron, which should be noted, is inertia. The material heats up for a long time and cools for a long time, which increases the efficiency of heat transfer.
This inertia can be considered both a positive quality and negative - in the event of a sharp warming in the street, the boiler will maintain a high temperature in the heating system for a long time.
A cast-iron boiler weighs twice as much as steel, so the boiler design is made sectional so that it is convenient to deliver, assemble and repair
Cast iron undergoes dry and wet corrosion. The latter contributes to the appearance of rust, but due to the thick walls, the corrosion process stretches for a long time.
The disadvantages of cast iron boilers include the fragility of the material, which manifests itself as a result of improper use - temperature changes, mechanical damage during transportation and installation.
Selection of equipment by type of smoke exhaust
The method of flue gas extraction is one of the most important factors when choosing gas equipment. It directly affects the choice of model, and the ability to install it in a particular room. Therefore, it is important to study possible smoke removal options and choose the best one.
Chimney type boilers
The combustion process in chimney-type boilers is ensured by natural draft, which uses the air from the room. The required amount of air enters through the open combustion chamber.
Cons of chimney floor boilers of double circuit type:
- Efficiency is several percent lowerthan with turbocharged gas equipment - part of the heat flies out into the pipe along with the smoke.
- Additional costs for the construction of the chimney. If everything is done correctly, in accordance with legislative standards, then you need to obtain additional permission, install a sensor that measures the level of carbon dioxide, annually invite a specialist to conduct an examination.
- Active condensation - Modern equipment has a higher efficiency and gives a small exhaust temperature at the outlet. As a result, especially if the chimney is not very insulated, condensation forms, which leads to the rapid destruction of the chimney walls.
- The need for adequate ventilation. As a result of combustion, warm air from the room is drawn into the chimney. In the presence of a chimney boiler, it is imperative to provide forced ventilation.
Due to the features of the mechanism of operation and operation, a separate room is required for the boiler room.
Equipment advantages:
- relatively low cost of the device;
- simpler design that is easier and cheaper to maintain;
- the ability to output combustion products to a greater distance from the house.
Due to its cost, durability and simple operation, floor chimney boilers are quite popular.
In cases where the house already has a ready-made chimney, which is correctly installed and working, experts advise not to spend money on more expensive models and install ordinary stationary equipment with a connection to the chimney, with an open combustion chamber.
The chimney can be led into the wall or through the roof. During installation, it is necessary to ensure its correct and safe assembly (+)
Parapet boiler: design features
Parapet boilers can be distinguished into a separate category of equipment for their placement, but they also have a feature related to the output of combustion products. They differ from stationary gas boilers by the need to connect a coaxial pipe to remove smoke.
The coaxial system looks like a pipe, which is located in the pipe. Chimney gases are vented through the inside, and air is drawn in from the outside through the outside.
Parapet boilers can be installed in rooms of any purpose, even in an apartment of a multi-storey building (if there is permission) and anywhere - on the windowsill or under it, instead of the battery. The only limitation in this case is the length of the horizontal section of the pipe should not exceed 3 m.
By their characteristics and structural features they resemble attachments, but, unlike them, are quite unpretentious in operation (+)
Turbocharged heating boilers
Sometimes, due to the lack of a chimney or architectural features of a building, chimney equipment cannot be installed. Then, a turbocharged boiler is used as a heating device.
This is a device in which the fuel combustion process is carried out in a closed chamber, and the flue gas emission is forced, by means of a built-in turbine, the rotation speed of which can be regulated - set to the optimum pressure.
By using the correct settings of the turbocharged boiler, maximum fuel processing and increased efficiency are achieved. This leads to significant gas savings (+)
Disadvantages of turbocharged double-circuit boilers of floor type:
- another point of expenditure in the event of a turbine breakdown;
- insignificant but additional noise that the fan makes;
- increase in energy consumption.
Compared to chimney boilers, turbine ones consume about 50 watts more.
The advantages of the equipment are as follows:
- Universality of application - the boiler can be installed in almost any room (private house, apartment).
- No access to open source of fire, reduces the likelihood of carbon monoxide entering the house.
- No need to install a chimney. A turbine boiler has a high cost, but due to the fact that it does not require the installation of a chimney, its installation is much cheaper. Savings on the purchase of pipes and the cost of installation services far outweigh the costs of more expensive equipment.
- The boiler does not draw air from the room, which means that heat loss is reduced. He takes air to maintain combustion from the street. Therefore, it does not require equipment in the supply ventilation room (although, in some cases, when replacing chimney boilers with turbine ones, the absence of additional ventilation leads to poor air exchange and increased humidity in the house).
There are differences between different types of boilers, but in general they are all designed for safe operation and a fairly high efficiency. The choice of model depends more on financial capabilities and specific operating conditions.
Double-circuit boiler ignition methods
Without an automatic ignition system, few imagine the comfortable use of gas heating equipment. There are two completely different principles that can be applied for both electric-dependent and fully autonomous boilers - electric and piezo ignition.
The automation unit for piezo ignition of a double-circuit gas boiler has a simple design and resembles a gas lighter device (+)
The piezo ignition method operates on the same principle as ignition in a lighter - pressing a button leads to the appearance of a spark that starts the combustion process. In the future, control that the flame does not go out, is carried out using a thermocouple.
The element is heated by the burner, generating a current that keeps the solenoid valve from slamming. During a temporary suspension, the wick still remains lit in the boiler.
Piezo ignition is often used in non-volatile boilers and is, in fact, a semi-automatic system. If the gas is turned off, the burner goes out and the valve closes, stopping further gas supply. You can start the boiler again by pressing the button.
Electric ignition provides complete automation - the heating device starts up with the appearance of a spark, and flame control is carried out using the ionization control unit.When the power is turned off, the automation is triggered, it shuts off the gas, and when turned on, it starts the operation of the boiler.
In such devices there is no need for a constantly burning ignition filter, and this is a significant gas saving. It is possible to eliminate the dependence of the electric ignition boiler on the power supply using batteries.
Use of coolants in boilers
If irregular living or frequent and long departures is planned in the country house or in a private house, and draining and purging the liquid from the system is not considered an acceptable option, then it is necessary to prevent freezing.
This can be done by adding antifreeze to the coolant - substances that do not freeze to a certain negative temperature, and in the case of even lower temperatures do not harden, but turn into a gel-like substance, without increasing in volume.
It is not recommended to use antifreeze in double-circuit floor boilers operating on gas, in most cases (for single-circuit boilers, these standards are less stringent). The instructions clearly indicate that the coolant in the heating system must be water.
If the user, at his own risk, pours not prepared water, but any other solution into the heating system, then the problems that arose because of this do not apply to warranty cases
Some manufacturers indicate a specific brand of antifreeze that can be used for pouring into the heating system. For example, a manufacturer of equipment Viessmann recommends using brand coolant Antifrogen.
Others indicate that, as an exception, antifreeze can be used if its manufacturer guarantees that the product does not harm the components and materials of the boiler, in particular the heat exchanger. It should be borne in mind that for a particular model one coolant may come up and not fit another.
Therefore, if it is important that antifreeze is used as the coolant in the heating system, it is necessary to find out before the purchase whether and if so, what brand of coolant is allowed to be used for a particular make and model of the boiler.
How to choose the power of a double-circuit boiler
One of the most important indicators to consider when buying gas heating equipment is power.
At the same time, it must be borne in mind that a too powerful boiler will lead to an excessive consumption of gas fuel, and insufficient power of the device will not be able to provide a comfortable temperature regime, or the equipment will work to the limit of its capabilities and will quickly fail.
Image Gallery
Photo from
Floor gas boilers are powerful equipment not designed for heating one apartment. Usually they serve a production facility, commercial establishment or apartment building from several consumers
Unlike single-circuit units operating in the heating season, double-circuit units operate year-round. It should be noted that the maximum heating of water in any seasonal period should not exceed the limit of 80º
It must be remembered that during the heating of the water, the heating circuit in the double-circuit boiler is not involved, but its wear is still due to the preparation of sanitary water. If the reduction in service life plays a role, it is better to purchase a single-circuit option + boiler or column
If it is decided to purchase a double-circuit boiler that serves heating with hot water, then the capacity calculated for heat supply should be increased by 20%
Turbocharged gas boilers of both floor and wall design are much safer and more reliable in operation, but at a price they are significantly ahead of atmospheric ones
Virtually all floor models of gas equipment are equipped with remote or built-in automation that interrupts the flow of gas in case of danger. Its presence increases the cost of units
According to the principle of power regulation, two-stage models and boilers with smooth modulation are considered the most economical. They reduce fuel consumption depending on real needs.
The requirement for a floor gas boiler is a separate boiler room. It is allowed to install in utility rooms with the obligatory presence of opening windows or at least windows
Floor boiler on the landing
Year-round operation of equipment
Single-circuit model paired with a boiler
Home Maintenance Unit
Turbocharged gas version
Gas boiler automation
The most economical solution
Location of the boiler in a separate room
Power calculation formula
It is hardly possible for an ordinary user to achieve accuracy in calculations, but you can try to get approximate figures. As a basis, it is necessary to take the specific power of the heating device, calculated for a particular region, multiply by the area of the heated room and divide by 10.
The specific power of the boiler is calculated separately for each region. To find out the indicator for a particular room, you must use the formula (+)
The result obtained is the required boiler power under ideal conditions.
Depending on the characteristics of the premises, it is necessary to amend:
- for rooms with a height of more than 2.8 m, for every 10 cm of the above number it is necessary to increase the initial value by 3%;
- two walls facing the street mean that it is necessary to increase the capacity by 15%;
- an unheated room on top requires an increase of 12%, from the bottom - by 7%;
- if from the entire area of the room the glazing occupies more than 8%, then for each excess of 1% add 1% of power;
- an external door that systematically opens increases heat loss by 15%.
When buying a double-circuit floor gas boiler, whether it is a floor or hanging model, you need to add another 20%. After all calculations, it is also recommended to add a small margin of power - so the load on the device will be less and it will last longer.
Auto Simulation Function
It is better that the boiler is not only selected according to the power level, but also has the function of its adjustment. There are devices with single-stage, two-stage and simulated power. The models of the latter two types are more efficient in operation, since they have the ability to adjust.
Since the need for maximum operation is no more than a third of the winter season, the possibility of adjustment can significantly save on heating and extend the life of the boiler
If the boiler has automatic power control, then it does not just turn on and off at the moment when it reaches the set temperature, it independently reduces the power to a minimum.
If the work in the minimum temperature mode is redundant, then only then the device goes into on-off mode.
Automatic power modeling increases energy savings, effectively affects equipment longevity and increases user comfort.
What else you need to pay attention to
In addition to power, the mass of technical characteristics of boilers affects the operation of a gas heating system.
More attention should be paid to the following parameters:
- Amount of gas consumed floor-mounted double-circuit gas boiler. You can choose an economical model by comparing products with the same power.
- Efficiency. One of the most important indicators affecting the economical use of energy resources. Leading manufacturers of gas equipment are working quite successfully on its increase - in modern devices it reaches about 100%.
- Hot water circuit performance. The indicator can be from 2.5 to 30 l / min.
- Power consumption in volatile equipment. On average, boilers can consume about 2 kW per day. About 60 kW per month
- Maximum temperature indicators. In the DHW system, they are about 55 ° C; in the heating circuit - up to 90 ° C.
- Water pressure. Values in the heating circuit reach 10 bar.
Only a thorough study and comparison of characteristics, user reviews, sellers, representatives of installation and repair and maintenance services who work with gas boilers will help determine the manufacturer of high-quality equipment among the many brands on the market.
It should be remembered that saving on the cost of the boiler can result in energy costs and repairs, and the high price does not always correspond to the objective cost and includes a premium for the brand
Additional selection recommendations, assessment of technical and operational characteristics of different models, as well as an overview of the best gas boilers are given in the articles:
- Floor gas heating boilers: types, how to choose, an overview of the best brands
- How to choose the best gas boiler: criteria for choosing the best option
- Double-circuit gas boilers: types, principle of operation, selection criteria + overview of the best brands
The principle of operation of a double-circuit gas boiler:
How to choose a gas boiler:
Choosing a device for heating a private house is a responsible and serious task. It so happens that having entrusted to the sellers of gas equipment, you have to pay for the mistakes of others or “bail out” sellers of obsolete equipment.
As a result, you get what you expect to receive at all. Often, it’s too late to realize that to understand the many characteristics of double-circuit floor gas boilers, their design features and system operation parameters, you would first have to yourself.
Have experience operating a dual-circuit floor-standing gas boiler? Tell us which model you use for heating a house, what are the features of its work. Share your impressions of operating the equipment with our readers. You can ask questions and leave comments on the article in the form below.